Building Confidence


Volume 20 Issue 4
ISSN 1923-7162


Welcome to Dave's Shop Talk's Home Improvement Newsletter of questions from our members on their construction projects, a Tip of the Month and a home remodeling article, both from our website at https://daveosborne.com.

Tips of the Month

When pulling finish nails out of a piece of molding, pull them all the way through from the back using a pair of pliers to avoid scratching or splintering the face of the wood.

If you are cutting on saw horses, it is a good idea to set the depth of the blade just below the surface you are cutting to avoid too much damage to the saw horses. It is also easier on the saw.

Ask Dave!

Hi, I am trying to calculate square footage of a floor plan that has a 1/8" = 1' scale. It measures 4 3/4" x 5". Can you tell me how to do this?

A scale of 1/8" = 1 foot. This means that a line measured in inches on the plan when multiplied by 8 is the number of feet full scale. For your example, a line that is 4 3/4" on the plan when multiplied by 8 is equal to 38 feet full scale. 4.75 X 8 = 38'. A line 5" on the plan id 40' full scale. Just make sure that your measurements taken from the plan are in inches multiplied by 8 (for this scale), giving the answer in feet, full scale. Square footage is calculated: 38 x 40 = 1520 sq. ft.

Hope this helps,

Dave

I have to replace the stairs to my deck as the wood is rotting with artificial decking boards. After I bought and cut the boards, I was advised that a third stringer would be required. I have the board but not sure how to measure, cut and make sure it is level with the two existing stringers. There are ten steps. This is new to me and would love any advice you may have to make this job go smooth.

Hopefully, you didn't install the stringers into the steps, yet. We usually layout one stringer, cut it out, dry fit it in place to be sure there are no mistakes and it fits okay, steps level, etc. Then we use this stringer as a template for the others - just trace around it on the new board. Then when we cut them out they are exactly the same.

Dave

How do I build a ledger for a stringer that is only catching 1" of my rim joist.

I like to support the stringer as in the drawings below:

Diagram of securing stairs showing box joist or header with stair stringer fastened to it.

Or another option is to incorporate the handrail into the support of the stringer:

Diagram of deck stairs showing how they are secured to the deck.

Hopes this helps,

Dave

Hello Dave I have a set of stairs that have 69.5 height and 97.3/4 and I did 6 15/16 rise and 11" run and I have to raise the stringer about an inch off the landing to be level. what did I do wrong?

Did you cut the thickness of the tread off the bottom of the stringer? The top of the stringer should be installed from the top floor, at 1 rise down plus the thickness of the tread, as well.

Dave

When installing new stair treads, should I glue each one before nailing? Should I use screws instead of nails? Thanks! Gary

Hi Gary, Yes, always glue new treads to the stringers and nail them with at least a 2 1/2" galvanized finish or truss head nail, for 1" treads. Set it below the surface. For 1 1/2" treads, use a 3" galvanized finish nail. The reason we don't use screws for threads is the size of the head. They do make a small head screw for handrails, etc. which can be found in finishing stores. Usually, glue and nails work well. For initial glue of treads to the stringer, I prefer a construction adhesive, applied from a tube. It fills any gaps left from saw cuts on the run of the stringer.

Dave

Feature Article of the Month

(taken from our website: DaveOsborne.com)

Electrical 3: Home Wiring Tips

VERY IMPORTANT! Before working on any electrical modifications of your home read the first article in this series: Electrical 1: Electrical Safety.

Circuits

Lights and plugs (duplex receptacles) circuits are 15 amp # 14 wire and can have up to 12 plugs or lights combined. It is best to combine plugs and lights, then if the circuit blows, some lights are still left on another circuit, so you are not totally in the dark. When connecting lights and plugs, keep them polarized with the black wire going to the brass screw and the white wire connecting to the silver screw. Only one black and white wire per fixture. To carry on to another fixture use a short wire, called a pigtail, to connect back to the circuit wire by using a marrette, or wire nut. Don't connect another wire to the double screw in the plug or light receptacle.

GFCI Rules

All plug outlets within 118" of a tub or shower must be a GFCI (Ground Fault Circuit Interrupter). All plug outlets within 118" of a wash basin must be GFCI. These first two do not apply to the washing machine or dryer plugs installed in a combined washroom, or bath and laundry room. All carport plugs must be GFCI.

All outdoor plugs are GFCI, except for the Christmas lights receptacle, in the soffit, if over 8' above the ground. All outdoor plugs should be on one circuit by themselves up to 12 plugs. Install the GFCI in the first receptacle from the panel, which will protect the entire circuit. Use only a 2 wire cable, a GFCI won't work with a 3 wire cable. Lights only, are not required to be protected by a GFCI.

Kitchen Plugs

Kitchen counter plugs are normally #14 - 3 wire 15 amp, split receptacle and should be within 36" of each other along the same counter. If the counter top is more than 12" wide it needs its own plug. These plugs are on a separate circuit, only 2 per circuit and not adjacent to each other.

A split receptacle is when the brass side of the receptacle is split, removing the tie between the two screws. Just twist it off with pliers. This creates two circuits - a black wire is attached to the one screw and a red to the other. The black and red wires are called the load and are directly attached to two separate breakers in the panel. The white wire is attached, as usual, to the silver screw with the tie left attached.

Notice on the panel the two main vertical bars on which the breakers are attached. Unless you shut off the main breaker, these are hot so don't touch them and hang onto the panel at the same time. Notice that the breakers attach to each of the bars alternatively.

When installing a double breaker for 220 volt or a split receptacle for two circuits, be sure to install the breaker so that the connections of the breaker attaches to alternate bars. Each bar is 110 volts. The black or red wire attaches to the breakers and the white wire attaches to the neutral bar obtaining 110 volts. For 220 volts the red and black are attached to opposite bars through the breaker without a neutral, the ground is attached to the ground or bonding bar.

In a dryer connection you need the red and black wires for the 220 volt element as well as the white for the neutral for 110 volt to run the motor and timers, light, etc. The 110 volt is obtained internally off the terminal block inside the dryer. 20 amp plugs are allowed in the kitchen, but must be wired with #12 wire and have a special 20 amp receptacle, only one 20 amp receptacle per circuit.

Receptacles

Receptacles around a room must be no further than 6' away, along a wall; most lamps, etc. have 6' cords. For these areas, don't count the swing of the door against a wall, windows that extend to the floor, fireplaces, or other permanent installations which limit the use of a wall.

All walls more than 36" need their own plugs. Bedroom plugs must now be protected with an arc-fault type breaker. A normal breaker will only trip with an overload, not a short. This new type will trip with both. Check this out in your area.

Hallways have their own rule, one plug within 15 ft of each other without going through a doorway.

Microwaves

Microwaves require their own circuit if installed in a built in cavity, or microwave shelf. These are 15 amp 14 wire. Otherwise, a counter plug will do.

Fridges

Fridges should be on there own 15 amp, #14 wire circuit. A clock receptacle is also allowed on this same circuit.

Junction Boxes

No hiding junction boxes, they should always be accessible.

Protective Plates

Nail protective plates over any wire less than 1 1/4 inches from the stud surface.

Hot Tub

A hot tub needs its own circuit, which depends on the size of its motor and heater. Contact your dealer for this. A GFCI breaker is also required. The heater is usually 220 volt, possibly needing 2 circuits, if the motor is 120 volt.

Wire Size

Amperage in relation to wire size. A 15 amp circuit at 120 volts is 1800 watts and requires a #14 wire. A 20 amp circuit at 120 volts is 2400 watts and requires a #12 wire. A 30 amp circuit at 240 volts is 7200 watts and requires a #10 wire and a 40 amp circuit at 240 volts is 9600 watts and requires a #8 wire.

If not absolutely sure of what you are doing while wiring your house, hire an electrician. Don't put your family and property at risk.

Better safe than sorry.

Almost the End

Read hundreds of diy articles, answered questions and dozens of plans and projects all written by Dave.

Become a Member and Dave will personally eliminate any doubts you might have about your projects by email.

Dan and I thank you for your interest and support of our Website. We hope we can help you with your present and future projects.

Get complete access to our website - Subscribe Now!

We BUILD CONFIDENCE. If you need advice on Building or on your projects at work or home you can make a very small investment and subscribe to our website, then send me any questions or uncertainties you might have via email. There is no extra charge. That is all part of your membership to our site!

Help us with the cost of putting this info out by becoming a member. Subscribe now!

Please tell your friends and family about our site and this Newsletter.

Dan and I wish all our readers and members of our website, all the best in 2022 and stay safe out there and thanks to our Front Line Workers. All of them.


Dave

(Ask Dave) (About Dave)



Your source for building tips, woodworking & furniture plans, house plans and building advice directly from Dave...

Hi, I'm Dave Osborne. With over 50 years experience as a journeyman carpenter, foreman and contractor in heavy construction I enjoyed working with apprentices and sharing the tricks of the trade that others shared with me. Now I get emails from Members all over the world and we include many of my answers in our Free Monthly Newsletters. Some of my answers include drawings and instructions specific to a project, but may also answer your questions. I use correct construction terminology, so you can confidently inform your building supply dealers or contractors exactly what you need.

ASK DAVE!

The Benefits of Membership

Membership gives you full access to our hundreds of how-to articles, woodworking plans, converters, calculators and tables. Our Stair Calculator is one of the most popular on the internet. We have projects you can build for (and with) your kids, furniture for your wife, and sheds and gazebos. If you run into a problem or need advice your Membership includes unlimited email questions to me through our Ask Dave quick response button.

Join us!








legal